Table 16-44 HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name
Property implementation
DeviceOperationalStatusPrevious Previous OperationalStatus values for Storage Volume
•
DeviceOperationalStatusPrevious[0]:
HPSA_StorageVolume.OperationalStatus[0]
•
DeviceOperationalStatusPrevious[1]:
HPSA_StorageVolume.OperationalStatus[1] (This
index is only populated if there is addional Vendor
unique status available)
15-4-7 Logical Drive Status Changed to ERROR
Table 16-45 HPSA_StorageVolumeIndication: Logical Drive status changed to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description Logical Drive Status has changed to ERROR status.
AlertingMangedElement WBEM path of the HPSA_StorageVolume class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 102
ProviderName HP Smart Array
RecommendedActions Check for failed or removed physical drives.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Logical Drive Status is now ERROR
EventCategory
6 (Primary Storage)
ProbableCause 86 (Disk Failure)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication