HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 16-42 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name
Property implementation
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion Physical Disk firmware version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer COMPAQ
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
15-4-5 Physical Drive Status Changed to PREDICTIVE FAILURE –
Solid State Wear Out
Table 16-43 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description Due to Solid State wear out a physical drive status has
changed to Predictive Failure .
AlertingMangedElement WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 204