HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 16-40 HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name
Property implementation
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWFirmwareVersion Physical Disk firmware version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer COMPAQ
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
15-4-3 Physical Drive Status Changed to REBUILDING
Table 16-41
HPSA_DeviceIndication: Physical Drive status changed to REBUILDING
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication