Table 16-39 HPSA_DeviceIndication: Physical Drive status changed to OK
Property name
Property implementation
HWFirmwareVersion Physical Disk firmware version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer COMPAQ
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
15-4-2 Physical Drive Status Changed to ERROR
Table 16-40 HPSA_DeviceIndication: Physical Drive status changed to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity Severity
5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description Physical Drive status has changed to an ERROR status.
AlertingMangedElement WBEM path of the HPSA_DiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 202
ProviderName HP Smart Array
RecommendedActions Check for physical drive failed or removed.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication