HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

The following properties are implemented.
Table 2-16
Class: HP_SystemXNCInstalledFirmwareIdentity
Property name Property implementation
CIM_InstalledSoftwareIdentity
HP_SystemXNCInstalledFirmwareIdentity
InstalledSoftware ref: HP_SystemXNCFirmware
System ref: HP_ComputerSystem
2-4 Supported indications
The following indications are implemented for ProLiant server platforms where available. System
indications are described in the following tables.
2-4-1 ASR Reboot Occurred
Table 2-17 HP_SystemHardwareIndication: ASR Reboot Occurred
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime
Time of indication
CIM_AlertIndication
Description The system has rebooted from a Automatic Server
Recovery (ASR) event
AlertingElementFormat 1 (Unknown)
AlertType 5 (Device Alert)
EventID 1
ProviderName HP Recovery
RecommendedActions Determine the nature of the ASR event and take
corrective action.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary ASR reboot occurred
EventCategory 16 (System Power)