HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 16-32 Class: HPSA_StorageCapabilities (CIM_StorageCapabilities)
Property name
Property implementation
ElementName For Primodial Pools: Controller name and location
Examples:
•
Smart Array in Slot 3, for internal
•
Active Controller: MSA500 in SystemCab03, for
external
For Concrete Pools: Controller name and
location:Array identifier
Examples:
•
Smart Array in Slot 3: Array – 0, for internal
•
Active Controller: MSA500 in SystemCab03: Array
– 1, for external
CIM_Capabilities
InstanceID Key: Opaque key
CIM_StorageCapabilities
DataRedundancyDefault
•
0—When number of drives < 1
•
1—When number of drives is an odd number)
•
2—When number of drives is an even number (For
example, pool can be configured for mirroring.)
DataRedundancyMax
•
0—When number of drives < 1
•
1—When number of drives is an odd number
•
2—When number of drives is an even number (For
example, Pool can be configured for mirroring.)
DataRedundancyMin 1
DeltaReservationDefault 0
DeltaReservationMax 0
DeltaReservationMin 0
ElementType 5 (Storage Pool)
NoSinglePointOfFailure
•
True—When number of drives > 1 (For example,
pool can be configured for redundancy.)
•
False
—
When number of drives <= 1
NoSinglePointOfFailureDefault
•
True—When number of drives > 1 (For example,
pool can be configured for redundancy.)
•
False—When number of drives <= 1
PackageRedundancyDefault
•
0 (When number of drives <= 1)
•
1 (When number of drives = 2 or 3)
• 2 (When number of drives > 3)
PackageRedundancyMax
•
0 (When number of drives <= 1)
•
1 (When number of drives = 2 or 3)
•
2 (When number of drives > 3)