HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 16-7 Class: HPSA_DiskDriveFirmware (CIM_SoftwareIdentity)
Property name
Property implementation
Manufacturer Disk drive vendor string
IdentityInfoType CIM:SoftwareFamily
IdentityInfoValue HPQ:
<TargetType value>
VersionString Drive firmware as reported from SCSI identify
command
HPSA_DiskDriveFirmware
15-3-7 HPSA_PhysicalPackage
HPSA_PhysicalPackage represents the overall physical package for the array system as a whole.
There is one instance per HBA or Storage Subsystem.
Table 16-8 Class: HPSA_PhysicalPackage (CIM_PhysicalPackage)
Property name
Property implementation
CIM_ManagedElement
ElementName Controller/Storage System name and location
Examples:
Smart Array in Slot 3, for internal
MSA500 in SystemCab03, for external
Description
Host Based RAID Controller, for Internal Controller
External RAID Controller, for External Controller
CIM_ManagedSystemElement
Name See Serial number implementation
CIM_PhysicalElement
CreationClassName HPSA_PhysicalPackage
Manufacturer Controller vendor string
Model Controller model string
PartNumber Not populatedNot available for this implementation
SerialNumber Controller Serial number for HBAs If serial number is not
available and if the controller is sitting in slot 0, then
this field displays as EMBEDDED.
Chassis serial number for External subsystems
Tag HBA / Subsystem Serial number
Version Not populatedNot available for this implementation
CIM_PhysicalPackage
RemovalConditions 2 (Not Applicable)