HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 14-30 HP_AlertIndication: Network Interface Connectivity Restored
Property name
Property implementation
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
13-4-7 Ethernet Team Member Status Change
Table 14-31 Optional HP_AlertIndication: Ethernet Team Member Status Change
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description An Ethernet Team member’s status has changed, further
information is available in the variable information of
this indication. This is an optional indication that can
be disabled through the Ethernet Event Provider
settings.
AlertingManagedElement WBEM path of the Ethernet Team
(HP_WinEthRedundancySet), reporting a member status
change.