HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 9-11 HP_ManagementProcessorIndication: Management Processor has been reset
Property name
Property implementation
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
1-4-3 Management Processor Reset Failed
Table 9-11 HP_ManagementProcessorIndication: Management Processor Reset Failed
Property name Property implementation
CIM_Indication
IndicationIdentifier
GUID string generated at indication
PerceivedSeverity 5(Major)
IndicationTime Time of indication
CIM_AlertIndication
Description
"Management Processor “ NAME” has not reset
successfully and may not be Operational. Here Name
is the name of the management processor
AlertingManagedElement WBEM path of the HP_ManagementProcessor instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 3
ProviderName HP MgmtProc
RecommendedActions None.
SystemName HP_ComputerSystem.SystemName
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication