HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 8-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded
Property name
Property implementation
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel
Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HP_MemoryHardwareIndication
AlertType
5 (Device Alert)
7-5-4 Memory Recovered from Degraded Redundancy
Table 8-30 HP_MemoryHardwareIndication: Memory Recovered from Degraded Redundancy
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
IndicationTime Time of indication
CIM_AlertIndication
Description The Advanced Memory Protection (AMP) system is
operating normally in the targeted configuration. If
redundancy was previously degraded, redundancy has
been restored. (TargetConfiguration), where
TargetConfiguration is
HP_MemoryRedundancySet.TargetConfiguration.
AlertingManagedElement WBEM Path of HP_MemoryBoard instance
representing the memory board
AlertingElementFormat 2 (CIMObjectPath)
PerceivedSeverity 2 (Information)
ProbableCause 1 (Other)
ProbableCauseDescription Advanced Memory Protection now Fully Operational
RecommendedActions No action is recommended.
EventID 4
EventTime Time of the event or time of the indication if event time
unknown