HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 8-28 HP_MemoryHardwareIndication: Memory Board Error
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
IndicationTime
Time of indication
CIM_ProcessIndication
CIM_AlertIndication
Description A memory board has an error. (MemoryBoardCaption)
where MemoryBoardCaption is the
HP_MemoryBoard.Caption for the failing memory
board.
AlertingManagedElement WBEM Path of HP_MemoryBoard instance
representing the memory board
AlertingElementFormat
2 (CIMObjectPath)
PerceivedSeverity 5 (Major)
ProbableCause 1 (Other)
ProbableCauseDescription Memory Board Error
RecommendedActions Check the memory configuration and replace the
memory board and memory modules as necessary.
Repair appropriate IML log messages after memory is
replaced.
EventID 2
EventTime Time of the event or time of the indication if event time
unknown
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.SystemName
ProviderName HP Memory
HP_AlertIndication
Summary Memory board error
EventCategory 3 (Memory)
OSType
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>