HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 8-27 HP_MemoryHardwareIndication: Memory Module Predictive Failure
Property name
Property implementation
Description A memory module has failed or is predicted to fail.
(MemoryModuleCaption), where MemoryModuleCaption
is the HP_MemoryModuleCaption for the failing
memory module.
AlertingManagedElement WBEM Path of HP_MemoryModule instance
representing the memory module
AlertingElementFormat 2 (CIMObjectPath)
PerceivedSeverity 5 (Major)
ProbableCause 1 (Other)
ProbableCauseDescription Memory Module Failed or Predicted to Fail
RecommendedActions Check the memory configuration and replace memory
as necessary. Repair appropriate IML log messages
after memory is replaced.
EventID 1
EventTime Time of the event or time of the indication if event time
unknown
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName HP_ComputerSystem.SystemName
ProviderName HP Memory
HP_AlertIndication
Summary Memory module has failed or is predicted to fail
EventCategory 3 (Memory)
OSType
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion The operating system version of the computer system
generating the indication in the following format:
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddress Contains a list of all the IP addresses of the computer
system generating the indication
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication