HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 8-7 Memory Board Status
Condition OperationalStatus[0]
StatusDescriptions[0]
OperationalStatus[1]
StatusDescriptions[1]
Memory board has a configuration
error, for example, there is a
problem with the board release
latch (unlock error) or there is an
improper configuration of memory
modules on the board.
3 (Degraded)
Memory board status: Degraded
3 (Degraded)
Memory board status:
Configuration error
7-4-5 HP_MemoryRedundancySet
The class HP_MemoryRedundancySet represents memory board redundancy on ProLiant servers
supporting advanced memory protection (AMP). There is one instance of this class on systems
supporting advanced memory protection. This class is not instantiated on non-AMP systems.
Table 8-8 Class: HP_MemoryRedundancySet
Property name
Property implementation
CIM_ManagedElement
Caption Memory Redundancy Set
Description Memory Redundancy Set for Advanced Memory
Protection
ElementName Memory Redundancy Set
CIM_SystemSpecificCollection
InstanceID HPQ:HP_MemoryRedundancySet:001
CIM_RedundancySet
TypeOfSet The type of redundancy currently in operation for the
Advanced Memory Protection system. This property
corresponds functionally to the property
CurrentConfiguration.
TypeOfSet[0] contains the current type of redundancy:
1 (Other), when the system is operating in
Advanced ECC mode
2 (N+1), when the system is operating in RAID
(XOR) mode
3 (Load Balanced), when the system is operating in
Mirrored mode
4 (Sparing), when the system is operating in Online
Spare mode
OtherTypeOfSet OtherTypeOfSet[0] contains the type of redundancy
when the property TypeOfSet[0] = 1 (Other). In this
case, the property will contain the value Advanced ECC
or Lockstep, otherwise the property is not populated.