HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 7-8 HP_SensorHardwareIndication: Temperature Sensor Caution Threshold Exceeded
Property name
Property implementation
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames Contains the temperature sensor threshold property
name that sets a value:
•
UpperThresholdNonCritical
•
UpperThresholdCritical
•
UpperThresholdFatal
VariableTypes 9 (sint32)
VariableValues HP_WinNumericSensor UpperThresholdNonCritical,
UpperThresholdCritical, or UpperThresholdFatal
property value that is set for the temperature sensor
detecting the exceeded threshold
ImpactedDomain
•
3 (Enclosure) for c-Class BladeSystems
•
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID *
Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>