Table 7-7 HP_SensorHardwareIndication: Temperature Sensor Recovery from Threshold Exceeded
Property name
Property implementation
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A temperature sensor has detected that the temperature
has returned to a normal operating range.
(SensorCaption)”, where SensorCaption is the
HP_WinNumericSensor.Caption for the temperature
sensor detecting a recovered exceeded threshold.
AlertingManagedElement WBEM path of the HP_WinNumericSensor instance
representing the temperature sensor detecting a
recovered exceeded threshold
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
ProviderName HP Temperature
RecommendedActions No action is recommended.
SystemName
HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary
Threshold exceeded condition recovery.
EventCategory 23 (System Cooling)
ProbableCause 52 (Threshold Crossed)
ProbableCauseDescription
Threshold Exceeded Condition has Recovered
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication