HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 7-2 Class: HP_NumericSensor
Property name
Property implementation
Description Temperature Sensor n detects for NumericSensorType.
StatusDescription.
n represents the number of the temperature sensor
instance, NumericSensorType represents the value of
NumericSensorType and StatusDescription represents
the value of StatusDescriptions[0]
ElementName Temperature Sensor n, where n represents the number
of the temperature sensor instance.
CIM_ManagedSystemElement
OperationalStatus[0]
2 (OK)If temperature reported by the sensor is
within normal operating range
2 (OK)If temperature reported by the sensor has
exceeded its non-critical threshold and has set fans
to full speed
6 (Error)If temperature reported by the sensor has
exceeded its threshold and the system is gracefully
shutting down
StatusDescriptions[0]
Temperature reported by the sensor is within
normal operating rangeIf temperature reported
by the sensor is within normal operating range;
Temperature reported by the sensor has exceeded
its non-critical threshold and the fans have been set
to full speedIf temperature reported by the sensor
has exceeded its threshold and has set fans to full
speed
Temperature reported by the sensor has exceeded
its threshold and the system is gracefully shutting
downIf OperationalStatus is 6 (Error)
HealthState
5 (OK)If OperationalStatus[0] value is 2 (OK)
20 (Major Failure)If OperationalStatus[0] value is
6 (Error)
Name Temperature Sensor n, where n represents the number
of the temperature sensor instance
CIM_LogicalDevice
CreationClassName HP_WinNumericSensor
DeviceID Unique identifier for this temperature sensor instance.
SystemCreationClassName HP_ComputerSystem.CreationClassName
SystemName
HP_ComputerSystem.Name
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)