HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 6-25 HP_SensorHardwareIndication: Fan Redundancy Gained
Property name
Property implementation
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
SolutionProductModel Conditional property containing the Solution Name
string when running in a aggregate product
environment in the format <aggregate product family
name> v<major>.<minor>.<update>
HP_HardwareIndication
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-8 Fan Redundancy Restored
Table 6-26 HP_SensorHardwareIndication: Fan Redundancy Restored
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description Cooling redundancy for the system has been restored.
(RedundancySetCaption), where RedundancySetCaption is
HP_WinCoolingRedundancySet.Caption of the cooling
redundancy set with restored redundancy