HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 6-23 HP_SensorHardwareIndication: Fan Redundancy Reduced
Property name
Property implementation
Description A fault tolerant fan is no longer providing cooling for a
cooling redundancy set. (RedundancySetCaption), where
RedundancySetCaption represents the
HP_WinCoolingRedundancySet.Caption for the
redundancy set with reduced redundancy.
AlertingManagedElement WBEM path of the HP_WinCoolingRedundancySet
instance representing the redundancy set with reduced
redundancy
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 5
ProviderName
HP Cooling
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Cooling redundancy reduced
EventCategory
23 (System Cooling)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Cooling Redundancy has been Reduced
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication