HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 6-22 Hp_SensorHardwareIndication: Fan Repaired
Property name
Property implementation
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has been repaired. The fan is now operating
properly. (FanCaption), where FanCaption is the
HP_WinFan.Caption for the fan that has been repaired
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the failed fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 4
ProviderName HP Cooling
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Fan Repaired.
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Repaired
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication