HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 6-19 HP_SensorHardwareIndication: Fan Removed
Property name
Property implementation
HWSerialNumber Conditional property containing the chassis serial
number when the chassis is a multi-node server chassis
5-4-2 Fan Inserted
Table 6-20 HP_SensorHardwareIndication: Fan Inserted
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity
2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A fan has been inserted. (FanCaption), where
FanCaption is the HP_WinFan.Caption for the fan that
has been inserted
AlertingManagedElement WBEM path of the HP_WinFan instance representing
the inserted fan
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 2
ProviderName HP Cooling
RecommendedActions No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Fan Inserted
EventCategory 23 (System Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Inserted
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication