Table 6-10 Class: HP_FanModule
Property name
Property implementation
StatusDescriptions[0]
Fan is operating properly”If
OperationalStatus[0] is 2 (OK)
“Fan has failed”If OperationalStatus is 6 (Error)
HealthState
5 (OK)If fan is operating properly;
20 (Major Failure)If fan has failed
Name Fan n, where n represents the number of the fan
instance
CIM_PhysicalElement
CreationClassName “HP_FanModule”
Tag Unique identifier for this fan module instance
CIM_PhysicalPackage
PackageType 7 (Fan)
RemovalConditions 3 (Removable when off)
4 (Removable when on or off)
HP_Fan
5-3-10 HP_FanSlot
HP_FanSlot represents fan slot on ProLiant Servers. There is an instance of this class for each fan slot in the
system, whether or not the slot is occupied.
Table 6-11 Class: HP_FanSlot
Property name Property implementation
CIM_ManagedElement
Caption Fan
n
, where
n
represents the physical lot number
CIM_Managed SystemElement
HealthState
5 (OK)If fan is operating properly
20 (Major Failure)If fan has failed
Name
Fan n, where n represents the physical lot number
OperationalStatus[0]
2 (OK)If fan is operating properly
6 (Error)If fan has failed
StatusDescriptions[0]
Fan is operating properly”If
OperationalStatus[0] is 2 (OK)
“Fan has failed”If OperationalStatus is 6 (Error)
“Fan slot is empty” if OperationalStatus[0] is
2(OK)