HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet
4-4-2 Power Supply Inserted
Table 4-25 HP_SensorHardwareIndication: Power Supply Inserted
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A power supply has been inserted.
(PowerSupplyCaption), where PowerSupplyCaption is the
HP_WinPowerSupply.Caption for the power supply
that has been inserted.
AlertingManagedElement WBEM path of the HP_WinPowerSupply instance
representing the inserted power supply
AlertingElementFormat 2 (CIMObjectPath)
AlertType
5 (Device Alert)
EventID 2
ProviderName HP Power
RecommendedActions
No action is recommended.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power Supply Inserted
EventCategory 16 (System Power)
ProbableCause
1 (Other)
ProbableCauseDescription Power Supply has been Inserted
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
•
For Windows 2008 32-bit: 76
•
For Windows 2008 64-bit: 77
•
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>