HP Insight Management WBEM Providers 9.0 for Windows Server 2003 and Windows Server 2008 Data Sheet

4-4 Supported indications
The following indications are implemented for ProLiant server platforms where available. System
power supply indications are described in the following tables.
4-4-1 Power Supply Removed
Table 4-24 HP_SensorHardwareIdentification: Power Supply Removed
Property name
Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A power supply has been removed. (Power Supply n),
where n is the system power supply number that was
removed
AlertingManagedElement WBEM path of the HP_WinPowerCollection instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
ProviderName HP Power
RecommendedActions Check the system power supply configuration. Verify
that this power supply was removed intentionally.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Power supply removed
EventCategory 16 (System Power)
ProbableCause 1 (Other)
ProbableCauseDescription Power Supply removed
ProviderVersion Provider version generating the indication in the
format,
<major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication