HP Insight Management WBEM Providers 2.80 for Windows Server 2003/2008 Event Log Messages Reference Guide

Table 2 Insight Provider Indications for Version 2.8.0 (continued)
Windows
Event ID
(short)
Windows
Event ID (full)
Windows
Event Source
DescriptionSummaryEvent
ID
Provider Name
112147483659
HP Smart
Array
A Smart Array controller
Cache status has changed
to Permanently Disabled.
The controller has detected
a problem with the cache
and has disabled the cache
permanently.
Array
controller
cache status
permanently
disabled11HP Smart Array
122147483660
HP Smart
Array
A Smart Array controller
Cache status has changed
to not configured. This may
be caused by a
configuration change.
Array
controller
cache status
not
configured12HP Smart Array
1011073741925
HP Smart
Array
A logical drive status has
changed from a non-OK
state to OK.
Logical drive
status OK101HP Smart Array
1023221225574
HP Smart
Array
A logical drive status has
changed to Error.
Logical drive
status error102HP Smart Array
1032147483751
HP Smart
Array
A logical drive is in a
degraded state. Device is
still servicing I/O but
redundancy may be
degraded or lost.
Logical drive
in degraded
state103HP Smart Array
1042147483752
HP Smart
Array
A logical drive is in a
degraded state. Multipath
support is Lost. Either cable
is removed or not
configured.
Logical drive
in degraded
state -
multipath
failure104HP Smart Array
2011073742025
HP Smart
Array
A physical drive status has
changed from a non-OK
state to OK.
Physical
Drive status
OK201HP Smart Array
2023221225674
HP Smart
Array
A physical drive status has
changed to Error.
Physical
drive status
Error202HP Smart Array
2031073742027
HP Smart
Array
A physical drive status has
changed to Rebuilding.
Data is now being rebuilt
onto this drive from the
RAID set.
Physical
drive is now
rebuilding.203HP Smart Array
2043221225676
HP Smart
Array
A physical drive status has
changed to Predictive
Failure.
Physical
drive status
Predictive
Failure.204HP Smart Array
2052147483853
HP Smart
Array
A Physical Drive is Currently
Offline but operational,
Secure Erase is in Progress.
Once the Secure Erase is
Complete, please reinsert
the same disk or new disk
for the disk to be
operational.
Physical
drive status
Secure
Erase.205HP Smart Array
2061073742030
HP Smart
Array
A physical drive is in
Online state. After Secure
Erase Operation
Physical
Drive status
Online206HP Smart Array
20 List of HP Insight Provider Indications