HP Insight Management WBEM Providers 2.80 for Windows Server 2003/2008 Event Log Messages Reference Guide
Table Of Contents

Table 2 Insight Provider Indications for Version 2.8.0 (continued)
Windows
Event ID
(short)
Windows
Event ID (full)
Windows
Event Source
DescriptionSummaryEvent
ID
Provider Name
3093221225781HP SCSI
A Storage Enclosure
Temperature sensor status
has changed to Critical. An
enclosure temperature is
reaching the maximum
allowed temperature for
normal operation. A
shutdown is imminent.
Action is required before
loss of data occurs.
Temperature
sensor status
Critical309HP SCSI
11073741825
HP Smart
Array
A Smart Array controller
status has changed from
non-OK to OK.
Controller
status OK1HP Smart Array
23221225474
HP Smart
Array
A Smart Array controller
status has changed to Error.
Controller
status Error2HP Smart Array
32147483651
HP Smart
Array
A Smart Array controller
redundancy state has
changed from Standby to
Active.
Controller
redundancy
state set to
Active3HP Smart Array
42147483652
HP Smart
Array
A Smart Array controller
has detected that
redundancy has been lost
due to failure or loss of
communication with partner
controller.
Controller
redundancy
lost4HP Smart Array
51073741829
HP Smart
Array
A Smart Array controller
has detected that
redundancy has been
restored and can
communicate with partner
controller.
Controller
redundancy
restored5HP Smart Array
61073741830
HP Smart
Array
A Smart Array controller
Battery status has changed
from non-OK to OK.
Controller
battery status
OK6HP Smart Array
72147483655
HP Smart
Array
A Smart Array controller
Battery status has changed
to Not Fully Charged.
Controller
Battery Status
set to Not
fully
Charged.7HP Smart Array
83221225480
HP Smart
Array
A Smart Array controller
battery status changed to
Failed.
Controller
battery status
Failed8HP Smart Array
91073741833
HP Smart
Array
A Smart Array controller
Cache status has changed
from non-OK to OK.
Controller
cache status
OK9HP Smart Array
101073741834
HP Smart
Array
A Smart Array controller
Cache status has changed
to Temporarily Disabled.
This may be caused by a
rebuild or configuration
change. Normal operation
will return after background
operations have completed.
Array
controller
cache status
temporarily
disabled10HP Smart Array
19