HP Insight Management WBEM Providers 2.80 for Windows Server 2003/2008 Event Log Messages Reference Guide

Table 2 Insight Provider Indications for Version 2.8.0 (continued)
Windows
Event ID
(short)
Windows
Event ID (full)
Windows
Event Source
DescriptionSummaryEvent
ID
Provider Name
83221225480HP SCSI
A SCSI physical drive status
is now set to Predictive
Failure.
SCSI
physical
drive
predictive
failure8HP SCSI
91073741833HP SCSI
A SCSI physical drive with
a status of Predictive Failure
that was located in the
system has been removed.
Physical
drive missing
was
Predictive
Failure9HP SCSI
103221225482HP SCSI
A SCSI physical drive is
offline and can no longer
return data. No further
status is available.
Physical
drive offline10HP SCSI
111073741835HP SCSI
A SCSI physical drive that
was located in the system
and had a status of offline
has been removed.
Physical
drive missing
was offline11HP SCSI
3012147483949HP SCSI
A Storage Enclosure Power
Supply status has changed
to non-redundant.
Power
Supply status
Non-Redundant301HP SCSI
3021073742126HP SCSI
A Storage Enclosure Power
Supply has changed to Fully
Redundant.
Redundant
power supply
status OK302HP SCSI
3032147483951HP SCSI
A Storage Enclosure Power
Supply status has changed
to Degraded Redundancy.
Power supply
status
Redundant
Degraded303HP SCSI
3041073742128HP SCSI
The storage enclosure fan
subsystem is operating
properly.
Fan status
OK304HP SCSI
3052147483953HP SCSI
A fan has failed, but there
are enough fans in the fan
subsystem to keep the
enclosure cool.
Fan status
Degraded305HP SCSI
3063221225778HP SCSI
A fan has failed and there
are not enough fans in the
fan subsystem to keep the
enclosure cool.
Fan status
Error306HP SCSI
3071073742131HP SCSI
A Storage Enclosure
Temperature sensor status
changed from non-OK to
OK.
Temperature
sensor status
OK307HP SCSI
3082147483956HP SCSI
A Storage Enclosure
Temperature sensor Status
changed to Warning
Condition. This indicates the
enclosure temperature is
above normal, otherwise
enclosure is still operating
normally.
Temperature
sensor status
Warning
Condition308HP SCSI
18 List of HP Insight Provider Indications