HP Insight Management WBEM Providers 2.80 for Windows Server 2003/2008 Event Log Messages Reference Guide
Table Of Contents

Table 2 Insight Provider Indications for Version 2.8.0 (continued)
Windows
Event ID
(short)
Windows
Event ID (full)
Windows
Event Source
DescriptionSummaryEvent
ID
Provider Name
2031073742027HP SAS
A physical drive status has
changed to Rebuilding.
Data is now being rebuilt
onto this drive from the
RAID set.
Physical
drive
rebuilding203HP SAS
2043221225676HP SAS
A physical drive status has
changed to Predictive
Failure.
Physical
drive
predictive
failure204HP SAS
3012147483949HP SAS
A Storage Enclosure Power
Subsystem status has
changed to non-redundant.
Power
Supply status
Non-Redundant301HP SAS
3021073742126HP SAS
A Storage Enclosure Power
Supply has changed to Fully
Redundant.
Redundant
power supply
status OK302HP SAS
3032147483951HP SAS
A Storage Enclosure Power
Supply status has changed
to Degraded Redundancy.
Power supply
status
Redundant
Degraded303HP SAS
3041073742128HP SAS
A Storage Enclosure Fan
status has changed from a
non-OK state to OK.
Fan status
OK304HP SAS
3052147483953HP SAS
A Storage Enclosure Fan
status has changed to
Degraded. An enclosure
has detected there may a
problem with one or more
of the fans.
Fan status
Degraded305HP SAS
3063221225778HP SAS
A Storage Enclosure Fan
status changed to Failure.
An enclosure has detected
a failure in the fan
subsystem and there is
insufficient fan capability to
ensure normal operation.
Fan status
Error306HP SAS
3071073742131HP SAS
A Storage Enclosure
Temperature sensor status
changed from non-OK to
OK.
Temperature
sensor status
OK307HP SAS
3082147483956HP SAS
A Storage Enclosure
Temperature sensor status
changed to Warning
Condition. This indicates the
enclosure temperature is
above normal, otherwise
enclosure is still operating
normally.
Temperature
sensor status
Warning
Condition308HP SAS
16 List of HP Insight Provider Indications