HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

HP Confidential
Table 4-20 Class: HP_Location
Property name Property implementation
CIM_ManagedElement
Caption Power Supply n, where n represents the power supply
position printed on the system labeling.
Description The location of the power supply n. Refer to power
supply position n printed on the system.
ElementName Power Supply n, where n represents the power supply
position printed on the system labeling.
CIM_Location
Name Unique identifier for this power supply location
instance
PhysicalPosition n, where n represents the power supply position
printed on the system.
HP_Location
ElementLocationTag Power Supply n, where n represents the power supply
position printed on the system.
ElementLocationTagDesc 0 (HoodTag)
4-3-20 HP_ElementLocation
HP_ElementLocation is used to represent an association between CIM_Location and
CIM_ManagedElement. The Windows® implementation class is
HP_WinPowerSupplyElementLocation.
Table 4-21 Class: HP_ElementLocation
Property name Property implementation
Element References CIM_ManagedElement
PhysicalLocation References CIM_Location
4-3-21 CIM_ConfigurationCapacity
CIM_ConfigurationCapacity is used to model power supply configuration capacity on ProLiant
Servers. The Windows® implementation class is HP_WinPowerSupplyConfigurationCapacity.
There is one instance of this class on systems modeling power supply configuration capacity.
Table 4-22 Class: CIM_ConfigurationCapacity
Property name Property implementation
CIM_ManagedElement