HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

23-4-6 Physical Drive Status Changed to Predictive Failure
Table 23-3 HP_SATADeviceIndication: Disk Drive status Predictive Failure
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Degraded/Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description A Disk Drive status has changed to Predictive Failure.
AlertingManagedElement WBEM path of the HP_SATADiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 605
ProviderName HP SATA
RecommendedActions Replace drive immediately to avoid loss of data.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive status Predictive Failure.
EventCategory 6 (Primary Storage Device)
ProbableCause 1 (Other)
ProbableCauseDescription Disk Drive State Changed to Predictive Failure
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>