Table 23-41 HP_SATADeviceIndication: Disk Drive status OK
Property name Property implementation
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_WinComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HP_DeviceIndication
DeviceModel Physical Disk Model string
23-4-4 Physical Drive Status Changed to Error
Table 23-42 HP_SATADeviceIndication: Disk Drive status Error
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description A Disk Drive status has changed to 'Error'.
AlertingManagedElement WBEM path of the HP_SATADiskDrive class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 603
ProviderName HP SATA
RecommendedActions Check for failed or removed physical drives.