HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 21-36 HP_TapeDriveDeviceIndication: Degraded Drive Now Missing
Property name Property implementation
IndicationTime Time of indication
CIM_AlertIndication
Description See HPWMITapeEventMetaData.mof
AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 510 (Degraded drive now missing)
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Tape
RecommendedActions See HPWMITapeEventMetaData.mof
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary See HPWMITapeEventMetaData.mof
EventCategory 7 (Secondary Storage Device)
ProbableCause 73 (Element Missing)
ProbableCauseDescription Missing tape drive that was Degraded
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication