HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 21-33 HP_TapeDriveDeviceIndication: OK Tape Drive Now Missing
Property name Property implementation
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
HP_HardwareIndication
HWFirmwareVersion Enclosure F/W version string (It must match the
HP_TapeDriveFirmware.VersionString)
HWManufacturer Enclosure Manufacturer string
HWSerialNumber Enclosure Serial Number (It must match the
HP_StorageEnclosure.SerialNumber)
HP_DeviceIndication
DeviceModel Enclosure Model string
HP_TapeDriveDeviceIndication
21-4-8 Failed Drive Now Missing
Table 21-34 HP_TapeDriveDeviceIndication: Failed Drive Now Missing
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description See HPWMITapeEventMetaData.mof
AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 508 (Failed drive now missing)
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Tape
RecommendedActions See HPWMITapeEventMetaData.mof
SystemName Name of the computer system generating the indication