Table 21-28 HP_TapeDriveDeviceIndication: Drive status changed to OK
Property name Property implementation
HWSerialNumber Enclosure Serial Number (It must match the
HP_StorageEnclosure.SerialNumber)
HP_DeviceIndication
DeviceModel Enclosure Model string
HP_TapeDriveDeviceIndication
21-4-3 Drive status changed to Degraded
Table 21-29 HP_TapeDriveDeviceIndication: Drive status changed to Degraded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Degraded / Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description See HPWMITapeEventMetaData.mof
AlertingMangedElement WBEM Path of HPSCSI_TapeDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 503 (Tape drive status changed to Degraded)
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP Tape
RecommendedActions See HPWMITapeEventMetaData.mof
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary See HPWMITapeEventMetaData.mof
EventCategory 7 (Secondary Storage Device)
ProbableCause 35 (Performance Degraded)
ProbableCauseDescription Tape drive performance is suboptimal. This could be
caused by bad cabling or configuration problems
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>