HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-76 HPSCSI_DeviceIndication: Temperature sensor status change OK
Property name Property implementation
HWLogicalLocation Enclosure Location string
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
17-4-16 Temperature sensor status change Warning
Condition
Table 17-77 HPSCSI_DeviceIndication: Temperature sensor status change Warning Condition
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 4 (Minor)
IndicationTime Time of indication
CIM_AlertIndication
Description The SCSI Storage enclosure temperature is outside of
normal operating range
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 24
ProviderName HP SCSI
RecommendedActions Ensure server cover is properly installed. Ensure all
empty disk drive bays are filled with drive covers.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary This SCSI Storage enclosure temperature status is
Warning
EventCategory 24 (Primary Storage Cooling)
ProbableCause 51 (Temperature unacceptable)
ProbableCauseDescription Temperature Status Changed to Warning Condition