HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-74 HPSCSI_DeviceIndication: Power Supply status OK
Property name Property implementation
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Enclosure firmware version string
HWLogicalLocation Enclosure Location string
HWManufacturer Enclosure Manufacturer string
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
17-4-14 Power Supply Status DEGRADED
Table 17-75 HPSCSI_DeviceIndication: Power Supply status DEGRADED
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description One of the component power supplies that make up
the redundant power supply has failed. The drive
system (either a drive subsystem or a power supply for
the main unit) continues to operate. However, if the
remaining power supply should fail, the drive system
will lose all power and data loss could occur
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 20
ProviderName HP SCSI
RecommendedActions Schedule replacement of redundant power supply
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication