HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 17-72 HPSCSI_DeviceIndication: Controller status ERROR
Property name Property implementation
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Controller firmware version string
HWLogicalLocation Controller Location string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
17-4-12 Power Supply status NOT REDUNDANT
Table 17-73 HPSCSI_DeviceIndication: Power Supply status NOT REDUNDANT
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 5 (Major)
IndicationTime Time of indication
CIM_AlertIndication
Description This SCSI Storage enclosure power supply was
redundant but due to a failure is not longer redundant
AlertingMangedElement WBEM path of the HPSCSI_StorageEnclosureProcessor
class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 22
ProviderName HP SCSI
RecommendedActions Replace failed or missing power supply module
SystemName Name of the computer system generating the indication