HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-71 HPSCSI_DeviceIndication: Controller status OK
Property name Property implementation
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Controller firmware version string
HWLogicalLocation Controller Location string
HWSerialNumber Controller Serial Number
HP_DeviceIndication
DeviceModel Controller Model string
17-4-11 Controller Status ERROR
Table 17-72 HPSCSI_DeviceIndication: Controller status ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 6 (Critical)
IndicationTime Time of indication
CIM_AlertIndication
Description SCSI HBA has failed and is no longer operating
AlertingMangedElement WBEM path of the HPSCSI_HBAComputerSystem class
instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)