HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-67 HPSCSI_DeviceIndication: Physical Drive status - Missing was FAILED
Property name Property implementation
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
17-4-7 Physical Drive status—Missing was Predictive Failure
Table 17-68 HPSCSI_DeviceIndication: Physical Drive status - Missing was Predictive Failure
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive that was located in the system and
had a status of Predictive Failure has been remove
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 12
ProviderName HP SCSI
RecommendedActions Check for this disk to have been removed
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive missing was predictive failure
EventCategory 6 (Primary Storage)
ProbableCause 73 (Element Missing)
ProbableCauseDescription Missing Physical Drive was Predictive Failure.
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication