HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 17-66 HPSCSI_DeviceIndication: Physical Drive status - Missing was OK
Property name Property implementation
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
17-4-6 Physical Drive status—Missing was FAILED
Table 17-67 HPSCSI_DeviceIndication: Physical Drive status - Missing was FAILED
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)
IndicationTime Time of indication
CIM_AlertIndication
Description A physical drive that was located in the system and
had a status of failed has been removed
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 10
ProviderName HP SCSI
RecommendedActions Check for this disk to have been removed
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Physical drive missing was failed
EventCategory 6 (Primary Storage)
ProbableCause 73 (Element Missing)
ProbableCauseDescription Missing Physical Drive was Error.