HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 17-62 HPSCSI_DeviceIndication: Physical Drive status set to OK
Property name Property implementation
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Disk firmware version string
HWLogicalLocation Disk Location string
HWManufacturer Disk Manufacturer string
HWSerialNumber Disk Serial Number
HP_DeviceIndication
DeviceModel Disk Model string
17-4-2 Physical Drive status set to ERROR
Table 17-63 HPSCSI_DeviceIndication: Physical Drive status set to ERROR
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity Severity (for example, 5 (Major))
IndicationTime Time of indication
CIM_AlertIndication
Description SCSI physical disk has a status of ERROR and can no
longer return data
AlertingMangedElement WBEM path of the HPSCSI_DiskDrive class instance
AlertingElementFormat 2 (CIMObjectPath)