Table 17-9 Class: HPSCSI_StorageEnclosure (CIM_Chassis)
Property name Property implementation
CIM_Chassis
HP_StorageEnclosure
Location See HP Storage Enclosure Profile
17-3-9 HPSCSI_StorageEnclosureProcessor
HPSCSI_StorageEnclosureProcessor represents the management processor within a Storage Enclosure.
This instance contains operational status for all managed components in the enclosure, if applicable.
Table 17-10 Class: HPSCSI_StorageEnclosureProcessor (CIM_ComputerSystem)
Property name Property implementation
CIM_ManagedElement
ElementName Enclosure location (for example, Internal Storage
System)
CIM_ManagedSystemElement
Name Enclosure index
OperationalStatus Operational status for enclosure and associated power
supplies, fans and sensors.
The use of OperationalStatus is described in the HP
Storage Enclosure Profile. Index values are populated
as follows:
OperationalStatus[0]—Enclosure status
0 (Unknown)
2 (OK)
3 (Degraded)
6 (Error)
OperationalStatus [1]—Fan status (See Profile)
OperationalStatus [2]—Power Supply status (See
Profile)
OperationalStatus [3]—Temp Sensor Status (See
Profile)
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not applicable)
RequestedState 12 (Not applicable)
CIM_System
CreationClassName HPSCSI_StorageEnclosureProcessor
IdentifyingDescriptions Other Vendor Specific Name