HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 16-80 HPSAS_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name Property implementation
HWSerialNumber Enclosure Serial Number
HP_DeviceIndication
DeviceModel Enclosure Model string
16-4-11 Enclosure Power Supply Status changed to OK
(Redundant)
Table 16-81 HPSAS_DeviceIndication: Enclosure Power Supply status changed to OK (Redundant)
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 2 (Info)
IndicationTime Time of indication
CIM_AlertIndication
Description A Storage Enclosure Power Supply has changed to
Fully Redundant.
AlertingMangedElement WBEM Path of HPSAS_StorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 302
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SAS
RecommendedActions No action is recommended.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Redundant power supply status OK
EventCategory 17 (Primary Storage Power)
ProbableCause 1 (Other)
ProbableCauseDescription Redundant Power Supply Status Changed to OK
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>