HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 15-128 HPSA_DeviceIndication: Controller Cache status—Permanently Disabled
Property name Property implementation
CIM_AlertIndication
Description Array Controller Cache Status is set to a status of
Permanently Disabled. Controller has detected a
problem with the cache and has disabled the cache
permanently.
AlertingMangedElement WBEM path to the HPSA_ArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 11
ProviderName HP Smart Array
RecommendedActions Check Cache controller error code. Run diagnostics.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Array Controller Cache Status is Permanently Disabled.
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication