HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 15-39 HPSA_DeviceIndication: Controller Battery status changed to Failed
Property name Property implementation
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
VariableNames
VariableNames[0]: FailureDescription
VariableNames[1]: CacheSizeTotal
VariableNames[2]: CacheSerialNumber
VariableTypes
VariableTypes[0]: 1 (String)
VariableTypes[1]: 5 (uint16)
VariableTypes[2]: 1 (String)
VariableValues
VariableValues[0]: Short Description of failure
VariableValues[1]:
HPSA_ArrayController.CacheSizeTotal
VariableValues[2]:
HPSA_ArrayController.CacheSerialNumber
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists