HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 15-113 HPSA_DeviceIndication: Physical Drive status changed to PREDICTIVE FAILURE
Property name Property implementation
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HWFirmwareVersion Physical Disk firmware version string
HWLogicalLocation Physical Disk Location string
For example, Port:1E Box: 1 Bay 5
HWPhysicalLocation Physical Location of the Failed Drive (Bay Number)
DeviceControllerLogicalLocation Controller Location
For example, SmartArray 642 in Slot 2
HWManufacturer COMPAQ
HWSerialNumber Physical Disk Serial Number
HP_DeviceIndication
DeviceModel Physical Disk Model string
15-4-5 Logical Drive Status Changed to OK
Table 15-114 HPSA_StorageVolumeIndication: Logical Drive status changed to OK
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Informational)
IndicationTime Time of indication
CIM_AlertIndication
Description A logical drive status has changed from a non-OK state
to OK
AlertingMangedElement WBEM path of the HPSA_StorageVolume Class
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 101
ProviderName HP Smart Array
RecommendedActions No action is recommended