HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 7-29 HP_MemoryHardwareIndication: Memory Redundancy Degraded
Property name Property implementation
VariableValues String containing the
HP_MemoryRedundancySet.InstanceID value.
ImpactedDomain 3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HP_MemoryHardwareIndication
AlertType 5 (Device Alert)
7-5-4 Memory Recovered from Degraded Redundancy
Table 7-30 HP_MemoryHardwareIndication: Memory Recovered from Degraded Redundancy
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
IndicationTime Time of indication
CIM_AlertIndication
Description The Advanced Memory Protection (AMP) system is
operating normally in the targeted configuration. If
redundancy was previously degraded, redundancy has
been restored. (TargetConfiguration), where
TargetConfiguration is
HP_MemoryRedundancySet.TargetConfiguration.
AlertingManagedElement WBEM Path of HP_MemoryBoard instance
representing the memory board
AlertingElementFormat 2 (CIMObjectPath)
PerceivedSeverity 2 (Information)