HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 7-27 HP_MemoryHardwareIndication: Memory Module Predictive Failure
Property name Property implementation
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
HP_HardwareIndication
HP_MemoryHardwareIndication
AlertType 5 (Device Alert)
7-5-2 Memory Board Error
Table 7-28 HP_MemoryHardwareIndication: Memory Board Error
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
IndicationTime Time of indication
CIM_ProcessIndication
CIM_AlertIndication
Description A memory board has an error. (MemoryBoardCaption)
where MemoryBoardCaption is the
HP_MemoryBoard.Caption for the failing memory
board.
AlertingManagedElement WBEM Path of HP_MemoryBoard instance
representing the memory board
AlertingElementFormat 2 (CIMObjectPath)
PerceivedSeverity 5 (Major)
ProbableCause 1 (Other)
ProbableCauseDescription Memory Board Error
RecommendedActions Check the memory configuration and replace the
memory board and memory modules as necessary.
Repair appropriate IML log messages after memory is
replaced.
EventID 2