HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 6-7 HP_SensorHardwareIndication: Temperature Sensor Recovery from Threshold Exceeded
Property name Property implementation
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain
3 (Enclosure) for c-Class BladeSystems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect
environment
SystemVirtualUUID Conditional property containing the virtual system
UUID when running in a Virtual Connect environment
6-4-2 Temperature Sensor Caution Threshold Exceeded
Table 6-8 HP_SensorHardwareIndication: Temperature Sensor Caution Threshold Exceeded
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 3 (Warning/ Degraded)
IndicationTime Time of indication
CIM_AlertIndication
Description A temperature sensor has detected that the temperature
has exceeded the normal operating range.
(SensorCaption) where
SensorCaption is the HP_WinNumericSensor.Caption
for the sensor that has failed.
AlertingManagedElement WBEM path of the HP_WinNumericSensor instance
representing the temperature sensor detecting the
exceeded threshold