HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet
Table 5-24 HP_SensorHardwareIndication: Fan Redundancy Lost
Property name Property implementation
Description Cooling redundancy has been lost.
(RedundancySetCaption), where RedundancySetCaption
represents the HP_WinCoolingRedundancySet.Caption
for the redundancy set that lost redundancy.
AlertingManagedElement WBEM path of the HP_WinCoolingRedundancySet
instance representing the redundancy set where
redundancy was lost.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 6
ProviderName HP Cooling
RecommendedActions Check the fan configuration and check the status of the
cooling redundancy. Ensure the system is being cooled
adequately. Add or replace fans if necessary.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Cooling redundancy lost.
EventCategory 23 (System Cooling)
ProbableCause 88 (Loss of Redundancy)
ProbableCauseDescription Cooling Redundancy has been Lost.
ProviderVersion Provider version generating the indication in the
format, <major>.<minor>.<revision>.<build>
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType
For Windows 2003 32-bit: 69
For Windows 2003 64-bit: 70
For Windows 2008 32-bit: 76
For Windows 2008 64-bit: 77
For Windows 2008 R2: 103
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication