HP Insight Management WBEM Providers 2.8 for Windows Server 2003 and Windows Server 2008 Data Sheet

Table 5-17 Class: CIM_ConfigurationCapacity
Property name Property implementation
CIM_ManagedElement
Caption Fan Configuration Capacity
Description This describes the number of fans that can be
configured.
ElementName Fan Configuration Capacity
CIM_PhysicalCapacity
Name Unique identifier for this fan configuration capacity
CIM_ConfigurationCapacity
ObjectType 3 (Fans)
Increment 1
MaximumCapacity Maximum number of fans
MinimumCapacity Minimum number of fans
5-3-17 CIM_ElementCapacity
CIM_ElementCapacity is used to represent an association between CIM_ConfigurationCapacity and
the computer system chassis that contains this configuration capacity. The Windows® implementation
class is HP_WinFanElementCapacity.
Table 5-18 Class: CIMElementCapacity
Property name Property implementation
Capacity References CIM_PhysicalCapacity
Element References CIM_PhysicalElement
5-4 Supported indications
The following indications are implemented for ProLiant server platforms where available. System fan
indications are described in the following tables.
5-4-1 Fan Removed
Table 5-19 HP_SensorHardwareIndication: Fan Removed
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at indication
PerceivedSeverity 2 (Information)